A direct drive motor is a type of motor used to drive a load directly without the need for any intermediate transmission structure. This type of motor is also known as a torque motor. By using high-energy magnetization, it generates high torque. Additionally, its air gap is planar, and the air gap magnetic field is axial, making it part of the axial magnetic field motor category

  • Product Details
Performance Parameters                                        Symbol            Unit             Series           Parallel
Continuous TorqueTcnN m3.53.5
Peak TorqueT pkN m10.610.6
Torque Constant±10%KtNm/Arms1.560.78
Back EMF Constant±10%KeV peak/rpm0.230.115
Motor Constant@25℃K mNm/Sqrt(W)0.3240.324
Line Resistance@25℃±10%R25Q11.52.88
Line Inductance±20%LmH20.15.02
Electrical Time ConstantTems1.631.63
Continuous Current (Natural Cooling)@100℃IcnA rms2.244.48
Peak CurrentlpkA rms6.813.6
Maximum Coil Temperaturetmax130130
Maximum Bus Voltage  UbusV dc310310
Pole Count2P 1414
Maximum Speed  QmaxRpm6001270
Mechanical Parameters
Total Mass (Natural Cooling)mnKg2.942.94
Moment of InertiaJrKg.m²0.001320.00132
Maximum Center Hole mm2020
Axial Runout μ m2020
Radial Runout μ m2020
Maximum Axial Load (Normal Mounting) N500500
Maximum Axial Load (Inverted/Side Mounting) N150150
Maximum Torque Load (Normal Mounting) Nm3030
Maximum Torque Load (Inverted/Side Mounting) N m1010
Encoder Parameters
A BI Incremental Optical Encoder (SIN/COS) Lines/rev81928192
A BI Incremental Optical Encoder(100x) counts/rev819200819200
A BI Incremental Optical Encoder(128x) counts/rev10485761048576
A BI Incremental Optical Encoder(200x) counts/rev16384001638400
A BI Incremental Optical Encoder(256x) counts/rev20971522097152
Repeatability Positioning Accuracy arc sec士3士3
Infomation
Ambient TemperatureOperating Temperature0℃ to 40℃(No Freezing)
Storage Temperature-15℃ to 70℃(No Freezing)
Ambient HumidityOperating Temperature  Operating Humidity Relative Humidity 10% to 80% (No Condensation)
Storage Temperature  Relative Humidity 10% to 90% (No Condensation)
Recommended Operating EnvironmentIndoor (No Direct Sunlight)

No Corrosive Gases, Flammable Gases, Oil Mist, or Dust